Nov 15, 2015 See Updated video: ElectraFit On Line Retrofit Guide Easily transform most Midmark and Ritter 111. Complete Line of Midmark/Ritter Exam Table and Chair Parts. Tilt Cylinders - Base Cylinders, Locking Gas Cylinders and Other Repair Parts. View and Download Midmark M11 installation & operation manual online. UltraClave Steam Sterilizer. M11 Medical Equipment pdf manual download.
. Go To Table Of Contents Installation Important Information & Operation Page 2 Manual Installation Page 4 Description M11 UltraClave™ Page 6 Steam Sterilizer Components Overview Page 8 Controls & Indicators Page 9 Operation Page 11 Operator Maintenance Page 20 Calling For. Go To Table Of Contents Owner’s Product Identification (information that you will need to provide for servicing - key information is highlighted) Date of Purchase Serial Number Name of Owner / Facility / Department Model Number Name of Authorized Dealer Telephone # of Authorized Dealer Address of Authorized Dealer MODEL AND SERIAL.
CONTENTS IMPORTANT INFORMATION.2 Scope and Purpose of This Manual.2 Intended Use of Product.2 Safety Instructions. 2 Explanation of Safety Symbols and Notes.3 Transportation and Storage Conditions.
3 INSTALLATION.4 Location Requirements For Sterilizer.4 Re-Location Requirements For Sterilizer. Intended Use of Product The M11 Ultraclave is intended to be used in medical and dental offices, hospi- tals, clinics, nursing homes, laboratories, and other facilities to sterilize heat sta- ble and moisture stable, reusable equipment. Dental handpieces can be sterilized in the M11 in the Pouches cycle.
Return To Table Of Contents Explanation of Safety Symbols and Notes Important Information DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. The DANGER symbol is limited to the most extreme situations. WARNING Indicates a potentially hazardous situation which, if not avoid- ed, could result in death or serious injury. Return To Table Of Contents INSTALLATION Location Requirements For Sterilizer DANGER Installation Do not operate this sterilizer in areas where flammable anes- thetics are used or stored. An explosion could occur, caus- ing personal injury. Adherence to the following recommendations for location of the sterilizer will contribute to optimum performance of the unit: MA439500 Support Surface (A) - Sterilizer must be placed on a level surface to ensure that. Return To Table Of Contents Support Surface Depth (C) - Support surface should be approximately 533 mm (21 in) deep.
Allow at least 51 mm (2 in) clearance behind the sterilizer for air circulation. Distance To Side Wall (D) - If the sterilizer is located next to side walls, there should be no less than 51 mm (2 in) clearance between the side of the sterilizer Installation and the wall. DESCRIPTION Operational Features The M11 UltraClave™ sterilizers. will begin a sterilization program cycle when a sterilization program is selected, the door is closed and fully latched, and the START switch is pressed.
Return To Table Of Contents program cycle is complete by sounding five audible “beeps”. The sterilizer may be switched to standby at this time or restarted if additional sterilization programs are desired. Mechanical Features Installation The M11UltraClave™ sterilizers. Return To Table Of Contents COMPONENTS OVERVIEW The illustration below shows the location of the sterilizer’s major components and the chart below provides their descriptive name. Components Overview MA439900 DESCRIPTION OF COMPONENTS 1. Access Cover 5.
Door and Dam Gaskets 2. Return To Table Of Contents CONTROLS & INDICATORS The following illustrations show the location of the sterilizer’s controls and indi- cators and the chart on the following pages describes their function. TEMP ( F) TIME (MIN: SECONDS) FILLING STERILIZING DRYING COMPLETE. Return To Table Of Contents Ref. Control Function Temperature / Time dis- alternately indicates cycle temperature and play exposure time when a cycle is selected.
Dur- ing a cycle, the cycle time remaining is dis- played. Pressure display indicates current chamber pressure during a cycle. Return To Table Of Contents Ref. Control Function START button when pressed, initiates the program cycle that has been selected. STOP button when pressed, terminates the program cycle currently in progress. ON / STANDBY button when pressed, turns the sterilizer ON or into STANDBY mode. Return To Table Of Contents Recommended Steam Sterilization Monitoring Pro- gram Physical monitors (temperature and pressure measuring devices) can be used to help detect failures in sterilizer function.
The sterilizer notifies the user if ster- ilization conditions fall outside of established limits. It is recommended that the Printer Accessory be used to create a record of each load’s actual cycle time, temperature, and pressure. Return To Table Of Contents 2. Open the door and pour distilled or demineralized water into the fill opening (2) until the water level found in the Level Indicator Tube (3) is at the top of the red / green fill level label (4). The M11 sterilizers are equipped with two large and two small trays to maximize the number of items that can be processed at one time and provide separation for better steam flow and penetration. Dental handpieces should only be sterilized when placed in a pouch and in the POUCHES cycle.
Only one handpiece should be placed in each pouch. The maximum M11 load shall be nine handpieces (in the pouch rack) and 75 in- struments. Other combinations of fewer handpieces and items can be pro- cessed in a single load if that allows for efficient sterilization.
Return To Table Of Contents Operation WARNING Do not use this sterilizer in an explosive or oxygen-rich atmo- sphere, or where flammable anesthetics are stored. To do so could result in an explosion or fire. Do not use this sterilizer for sterilizing volatile substances or for any purpose other than its intended design.
Return To Table Of Contents hide TEMP ( F) TIME (MIN: SECONDS) FILLING STERILIZING DRYING COMPLETE WATER LOW DOOR AJAR ERROR PRESSURE (PSI) UNWRAPPED POUCHES LIQUIDS PACKS START STOP ON/STANDBY MA439200 1. Press the ON / STANDBY button (1).
Return To Table Of Contents. The sterilizer automatically begins processing its sterilization load. The FILLING lamp (5) illuminates and the chamber automatically fills to the correct level. The STERILIZING lamp (6) illuminates, indicating that the sterilizer is in the heating and sterilization phase of the selected cycle. Return To Table Of Contents Standard Cycle Parameters The following table lists the standard cycle parameters for the four different types of sterilizer loads (follow state and federal guidelines regarding steriliza- tion of single use devices and instruments). Standard Cycle Parameters CYCLE TEMP / PRES- ITEMS TO BE STERILIZED. Return To Table Of Contents.
M11 Sterilizer Deep Tray 9A225001. Sterilizer Pouch Rack 9A226001. M11 Horizontal Cassette Rack 9A215001. M11 Vertical Cassette Rack 9A215002 OPERATOR MAINTENANCE It is the responsibility of the user to establish a periodic maintenance procedure to assure correct operation of the equipment and reliable sterilization of the loads. Return To Table Of Contents (a) Drain reservoir and fill with clean, distilled water then add one ounce of Speed Clean Sterilizer Cleaner to a cool chamber. (b) Run one 30 minute cycle (PACKS) at 121°C (250°F). Instruments must not be sterilized while cleaning the sterilizer.
(c) Drain reservoir fill with clean distilled or demineralized water and run one 3 minute cycle (UNWRAPPED) at 132°C (270°F). Return To Table Of Contents (a) Remove the top inspection cover (1).
(b) Select the UNWRAPPED cycle and START the cycle. WARNING The pressure relief valve will be hot. Do not use bare hands to pull wire ring; use a screw- driver or rod. Return To Table Of Contents 3. Cleaning Chamber Filter: (a) Before performing this pro- cedure, make sure that the sterilizer has cooled to room temperature.
(b) Open the sterilizer door and remove all trays, tray rack, and tray plate from the chamber. Return To Table Of Contents (a) Open sterilizer door.
Then, remove dam gasket (1) and door gasket (2) from door (3). (b) Clean the gaskets (1 and 2) with a mild detergent and inspect the gaskets for cracks, cuts, shrinkage, or swelling. Return To Table Of Contents Troubleshooting Guide - (Continued) Problem Possible Cause Solution Sterilization failure sterilization conditions reload the sterilizer in evidence from process were not present at the accordance with Guidelines monitor (chemical location of the indicator.
For Loading Trays. If the indicator, biological problem recurs, take the indicator, etc.). Return To Table Of Contents Troubleshooting Guide - (Continued) Problem Possible Cause Solution sterilizer is not level level the sterilizer. Input voltage is too low. Have a qualified electrician connect sterilizer to a separate (dedicated) circuit with proper voltage level.
Error Code Guide Use the following table to determine the meaning of an error code and assist in correcting minor problems with the sterilizer. Return To Table Of Contents Error Code Guide - (Continued) Problem Possible Cause Solution Error Code 5 sterilizer overloaded with reload the sterilizer in (excessive pressure) gauze or linen packs. Accordance with Guidelines for Loading Trays. If the problem recurs, take the unit out of service and contact an authorized service representative (see. Calling For solve your question or problem with your dealer, call the following number: Service Outside CE Union 1-800-Midmark (1-800-643-6275) 8:00 a.m until 5:00 p.m. (Eastern Standard Time in the U.S.) Monday thru Friday, except for standard U.S. Inside CE Union 33-2-430-517-76 Promotal 22, Rue De St.
“Exclusions”) manufactured by Midmark to be free from defects in material and Warranty workmanship under normal use and service. Midmark’s obligation under this war- ranty is limited to the repair or replacement, at Midmark’s option, of the parts or the. (1) year for all warranted products and components. EXCLUSIONS This warranty does not cover and Midmark shall not be liable for the following: (1) repairs and replacements because of misuse, abuse, negligence, alteration, acci- dent, freight damage, or tampering; (2) products which are not installed, used, and properly cleaned as required in the Midmark “Installation”. Return To Table Of Contents Installing the Printer WARNING Disconnect all electrical power to the unit before removing any of the unit’s covers/ shrouds or making any repairs to prevent the possibility of electrical shock. Failure to comply with these instructions could result in serious personal injury or death. Return To Table Of Contents 6.
Ritter 119 Manual
Plug PCB printer harness (1) into PC board (2). Route PCB printer harness (1) through harness clip (3) to prevent harness from contacting hot pressure relief valve. Place the printer (4) on the top cover in the recessed area. Return To Table Of Contents 10.
Ritter 119 Service Manual
Insert two tabs (A) of right hand side panel (1) into two slots (B) of base (2). Raise top edge of right hand side panel (1) into position under top cover (4) and secure using two screws (3).
Return To Table Of Contents Operating the Printer The paper feed switch on the printer is a rocker type switch. Push the left side (A) of the rocker switch to toggle the printer ON and OFF. Push the right side (B) of the rocker switch to ON / FEED position to advance the paper. Return To Table Of Contents 6. While holding the paper (1) in place, press the right side (B) of the switch to the ON / FEED position and hold.
The printer will activate and a rubber roller will put the paper into the printer compartment. Continue to hold the switch down until the paper emerges from the top of the printer mechanism. Return To Table Of Contents Installing a New Cartridge Ribbon 1.
Ritter 119 Service Manual
Press the left side (A) of the rocker switch to toggle the printer OFF (the lamp will turn off). Four small grooves (1) are embossed on the left and right side of the printer cover.
Return To Table Of Contents Removing the Paper Roll EQUIPMENT ALERT Be sure to pull the paper out of the top of the printer (paper cutter side). Pulling the paper out of the back of the printer will damage the printer mechanism. Before removing the paper roll, advance the paper about 2.5 cm (1 in.) beyond the paper cutter by pressing down and holding the switch to the ON / FEED po- sition. Return To Table Of Contents The figure below shows an example of a typical printout of a program cycle: Typical Printout of a Program Cycle READY BEGIN SET TEMP: 270F TEMPERATURE SET TIME: TIME RUN # CYCLE NUMBER DATE HEAT UP 00.0 00.0 00.0. Return To Table Of Contents NOTES. Return To Table Of Contents NOTES. Return To Table Of Contents.
Return To Table Of Contents Midmark Corporation 60 Vista Drive P.O. Box 286 003-1030-00 Rev. F (3/03) Versailles, Ohio 937-526-3662 Fax 937-526-5542 midmark.com.
Don't Take Our Word For It. 'My Statim 2000 stopped working.
Benco dental came down and said the thermal fuse and computer board was bad Wally, thank you and your company for providing great customer service and all the help I needed to fix my autoclave. My tech told me my STATIM 2000 repair could either be about $350 (if it was only the thermal fuse) or up to $1500 if it was another problem. Craig Haruki DDS Lihue, HI 'It was a pleasure working with Wally who saved me thousands over what I would have had to pay when the Patterson tech.' Dr Joseph Whitehouse Castro Valley, CA Well, that same autoclave is once again working like a champ thanks to allclaveparts.com. Steve Douglas, DDS Indianapolis, IN.